A Guide to Outdoor LED Parking Lot Lights

When choosing the best LED lighting solutions for your parking lot, several key factors should guide your decision. 

These include types of lights, energy efficiency, lighting controls, and beam angles, among others. Each element plays a crucial role in ensuring the safety, efficiency, and cost-effectiveness of your lighting installation.

Introduction

With the development of the economy, cars have become a common means of transportation for people. The urban parking lot makes the cars in the city run normally and smoothly. The parking lot is developing into an indispensable element of a city, and its illumination should also be paid attention to. Targeted lighting in the parking lot ( Click here to view case studies of LED parking lot lights for commercial districts. ). is not only a requirement to ensure use, but also a need to ensure property and personal safety.

Most parking lot lights use one of three types of lamps: high-intensity discharge (HID) lamps, such as metal halide lamps, high-pressure sodium lamps, and – if they’re very old – mercury vapor lamps. However, with the development of LED technology, LED parking lot Lights are gradually replacing traditional parking lot lights.

If you have a plan to upgrade your old car park, start by taking a full inventory of the car park and adjoining areas. The list should state the total number of lamps, type of lamps, number of poles, and location of poles. We can determine the wattage of LED lamps according to the wattage of the original lamps and the type of lamps. At the same time, add lamps to places that require additional lighting, and reduce the use of lamps in places that do not require much lighting.

If your parking lot is new, we believe you must have drawings of this parking lot (approximate square feet of the parking lot), including the dimensions of the parking lot, the location of the light fixtures, and the height of the light poles. Which areas need to be illuminated and which areas should not be illuminated by lamps temporarily. Then we can quickly start working on lighting simulations and give you the right LED solution.

ZC Lighting is also a professional expert in Street Lighting, more information visit street lighting design guide.

Design considerations

When you calculate lights, be sure to pay attention to which type of lights are used in different places (Lights near parking lot entrances and doors may differ from lights installed further away in parking lots). Remember that lighting distribution is key when considering a good design. To get a good result, lighting should be fairly even for a parking lot. Of course, better lighting doesn’t mean more lighting, too much light or uneven light distribution can cause light pollution or glare problems.

General requirements for outdoor parking lot lighting

  • Outdoor parking lot lighting shall be designed to provide adequate vision, comfort, and safety.
  • Outdoor parking lot lighting shall be designed to provide uniform lighting throughout the facility with no dark patches or pockets.
  • Outdoor parking lot lighting shall be designed to provide a minimum value of lighting necessary for the safety and identification of features.
  • Outdoor parking lot lighting shall not cause direct illumination on adjacent and nearby properties or streets. Fixtures should be of a type or adequately shielded so as to prevent glare from normal viewing angles.
  • In order to direct light downward and minimize the amount of light spilled into the dark night sky, all lighting fixtures serving outdoor parking lots, except as allowed in a subsection of this section, shall be full cutoff fixtures as defined by the Illuminating Engineering Society of North America (IESNA).
  • The maximum allowable installation height for lighting fixtures in open parking lots shall be 15 feet within 50 feet of low and medium-density residential areas and on rooftops. Other outdoor parking lot lighting fixtures can be 25 feet.

Relative standards-Lux and light uniformity

Below is the US standard

Basic1 Enhanced Security2
Minimum Footcandles on Pavement 0.2 FC1 0.5 FC
Maximum Footcandles on Pavement 4.0 FC 7.5 FC
Uniformity Ratio Maximum: Minimum 20:1 15:1
Minimum Footcandles at five feet Above Pavement 0.1 FC 0.25 FC
  • 1: 1 FC equals 10.7 lux
  • 2: Enhanced security is needed where special security needs exist, or where vandalism or crime is possible.

Below is the China Standard.

Parking lot classification Average lux on ground Uniformity
(minimum lux/ average lux)
GR Ra
Class I: > 400 vehicles 30 0.25 50 20
Class II: 251- 400 vehicles 20 0.25 50 20
Class III: > 101-250 vehicles 10 0.25 50 20
Class IV: ≤100 vehicles 5 0.25 55 20

Lighting distribution

The important thing you must consider is to perform a photometric analysis. Lighting design and simulation will help to have the best possible lighting design so that the area is properly lit. According to the Luminaire Classification System, the light should have a BUG value: backlight, upplight, and glare. The luminaire cannot have any upplight which will spill light into the night sky. Meanwhile, if the parking lot is near a residential area, there should be less backlight to make sure that we will not get many complaints from the residents.

Lighting distribution is the main feature of LED lights. With the help of a lens, the light that comes from the luminaire can project onto an object or a surface evenly. It is determined by the point at which 50% of the fixture’s luminous intensity is met. The lighting industry has created a classification system and recognized five distinct LED distribution types – Type I, Type II, Type III, Type IV, and Type V light distribution.

Generally, Type III, Type IV, and Type V are suitable for parking lot lighting, but roads entering parking areas and roads inside of parking lots often require spectrums like Type I and Type II. For example, in the below solution, we used Type I for the road in this industry area. But we used Type III for its parking lot area.

Dialux simulation

CCT

Correlated Color Temperature (CCT) is used to describe the color appearance of a light source. The value is expressed in Kelvin (K). The CCT of a warm light source is less than 3500k. The CCT of neutral light sources is in the 3500 to 4500k range. The CCT of the cold light source is greater than 4500k (see Figure 6). CCT is not a performance metric: higher numbers are not better. Rather, it is a metric that describes the temperature or temperature of the light.

Now more and more customers want the color temperature to be less than 3000K because they think that such a light source is closer to traditional lamps and does not look so dazzling which is not harmful to the eyes.

CRI

Color Rendering Index (CRI) is used to describe the color rendering accuracy of a light source. It is important to note that CRI only describes one aspect of color. CRI≤60 indicates poor color rendering, 60 – 70 medium, 70-80 good, 80-90 very good, 90+ excellent. CRI is a performance indicator, and the higher the value, the better. In parking lots, color recognition is necessary to identify clothes, faces, license plates, and vehicles. Generally speaking, a CRI greater than 70 is sufficient for parking lot lighting.

Height of Poles

Parking lot lights can be installed from 12 feet to 20 feet in height, but in some cases can be as high as 25 feet or 35 feet. The size of your parking lot will be used to determine the recommended height for your poles; larger areas are better for higher poles for better uniformity and vice versa.

Another aspect to consider is whether your area is urban (more concentrated in housing) or rural (more scattered). If your parking lot is adjacent to a lot of other houses, it is necessary to use shorter poles to ensure that the light does not interfere with the residential area. Conversely, in rural areas, you can have higher poles.

Space of Poles

Once the installation height is confirmed, you can then determine the spacing between your lamp poles. A rule of thumb: The higher your installation height, the fewer poles you’ll need. 

Continuing the previous example, in more densely populated areas you should have more and closer light poles, while in rural areas you will have fewer lamp poles. 

Type of mounting

There are different types of mounting for parking lot lights, including the Pole Mount and the Surface Mount. Pole mounted parking lot light is mounted on a pole, which has an arm that extends into the ground. Surface mount lights are with U-brackets or trunnion brackets that mount directly to an existing wall. Hylele LED parking lot lights have different kinds of brackets that can fulfill your installation requirements. Below is the diagram of brackets and their application. We are also providing parking lot light poles for your lighting system, so if you are interested in poles and brackets, please feel free to get in touch with us.

Lighting controls to save energy

The parking lot is lit for long periods every day. During certain hours of the night, the parking lot is with few vehicles and pedestrians. Installing energy-efficient equipment is a step toward an energy-efficient design, and lighting controls are a great addition. Ideally, it is best to install the controls at the same time as any new or replacement equipment is installed, as the electrician is already on site.

Controls are appearing in car parks due to new technologies capable of producing significant energy savings based on high-efficiency lighting. Lighting control includes a Timer switch, Photocell switch, Timing dimming, Motion sensor, and Smart control. Here we give a brief introduction, if you are interested, you can refer to our article about street light control systems.

Timer switch control system

Because parking lot lamps must be turned on and off regularly, they are typically controlled by a time switch, also known as a street lamp time switch control system. In the long run, a street lamp with a time switch management system will improve energy efficiency and service life, providing people with an outstanding user experience.

Photocell switch control system

A photocell switch is made up of two components: a photocell and a bimetallic relay. When the light intensity varies, the machine automatically switches on or off the illumination. The photosensitive resistance inside the light control gets less resistant as light shines on it. The parking lot light is then turned off and the circuit is closed.

When the ambient light is insufficient, the photosensitive resistance has a higher resistance value. The circuit is then turned on, and the parking lot light is switched on.

Timing dimming control system

Timing dimming is a technique that has been used for a long time. This is a dimmer function that allows you to modify the output of your LED parking lot light at night.

Traditionally LED drivers have a pre-programmed program. For example, we set the LED driver to run at 100% for 6 hours, 50% for the next 6 hours, and then 100% for the next 2 hours.

When the light is switched on at 18:00 and turned off at 6:00, the brightness is 100 percent from 18:00 to 24:00, and 50 percent from 24:00 to 6:00. In this way, we can save lots of energy at night when it’s not necessary to provide much light on parking lots.

Motion sensor

Motion detectors are triggered by the motion of vehicles and pedestrians. When a person enters the sensing range, the high output will continue to be maintained, while after the person leaves, the switch delay will automatically turn off the load. In this way, the utility of energy can be effectively saved without affecting the functional use of the parking lot.

Smart control system

ZC Lighting also provides a smart street lighting control solution, which is a remote management solution that guarantees the appropriate quantity of light is given where and when it is required. It allows users to turn on or off their parking lot lights, adjust the dimming level, verify lamp status, and monitor the data system. Street lighting control systems can use these features to increase energy efficiency, identify lighting outages, and resolve other maintenance concerns in real-time.

ZC Lighting parking lot lighting solutions

Easy to install and simple to maintain


Our LED parking lot lights ( Explore LED parking lot lights for commercial district applications. ) and LED floodlights are designed with high-quality mechanical solutions to ensure easy installation and simple maintenance, thereby reducing the operating costs of parking lot lighting.

Energy conservation and remote control


ZC Lighting places particular emphasis on developing solutions that can reduce the energy costs of devices with longer ignition times, such as parking lot lighting.
We have designed a variety of optical components to achieve greater lighting flexibility and distribute light only where it is needed.

Our LED parking lot lights and LED floodlights are also equipped with dimming systems and remote controls, allowing for switch programming and reducing overall lighting costs.

Consultation and technical support


ZC Lighting possesses professional technical knowledge and experience, which can assist customers in designing and selecting the most suitable products to illuminate parking lots following current regulations.

Your parking lot is an important part of the first and lasting impression you make on the public. A dimly lit, the potholed parking lot is often a bad experience. What’s more, a poorly lit parking lot often leads to accidents and crime.

But a clean, well-lit, and well-maintained parking facility is a community asset. Investing in making your property stand out for security and attractiveness makes good business sense.LED street lights LED post top lights, LED area lights, and LED flood lights can all be used for parking lot lighting. And we have all these kinds of LED lights for your options. Btw, our LED light can be with different lighting distributions, different wattages, and different installation brackets. We believe that you can find a suitable solution at ZC Lighting.

Summary

Hope this article can give you a better understanding of most aspects of outdoor parking lot lighting, including lighting requirements, performance requirements of lamps, pole of street light arrangement, lamp installation, how to achieve energy saving, etc. If you have plans to install LED lighting for your parking lot, you can contact us to provide you with a detailed solution. If you are still hesitant to reform your parking lot, then you can calculate the cost of replacing traditional lighting with LED lighting and the payback period, maybe it can help you make up your mind to choose a green LED solution.